Description
Empirical methods of beam angle optimization (BAO) are tested against the BAO
that is currently employed in Eclipse treatment planning software. Creating an improved
BAO can decrease the amount of time a dosimetrist spends on making a treatment plan,
improve the treatment quality and enhance the tools an inexperienced dosimetrist can use
to develop planning techniques. Using empirical data created by experienced dosimetrists
from 69 patients treated for lung cancer, the most frequently used gantry angles were
applied to four different regions in each lung to gather an optimal set of fields that could
be used to treat future lung cancer patients. This method, given the moniker FAU BAO,
is compared in 7 plans created with the Eclipse BAO choosing 5 fields and 9 fields. The
results show that the conformality index improved by 30% or 3% when using the 5 and 9
fields. The conformation number was better by 12% from the 5 fields and 9% from the 9
fields. The organs at risk (OAR) were overall more protected to produce fewer
nonstochastic effects from the radiation treatment with the FAU BAO.
Note

Includes bibliography.

Language
Type
Extent
98 p.
Identifier
FA00004280
Additional Information
Includes bibliography.
Thesis (M.S.)--Florida Atlantic University, 2014.
FAU Electronic Theses and Dissertations Collection
Date Backup
2014
Date Created Backup
2014
Date Text
2014
Date Created (EDTF)
2014
Date Issued (EDTF)
2014
Extension


FAU

IID
FA00004280
Organizations
Person Preferred Name

Doozan, Brian

author

Graduate College
Physical Description

application/pdf
98 p.
Title Plain
Empirical beam angle optimization for lung cancer intensity modulated radiation therapy
Use and Reproduction
Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

2014
2014
Florida Atlantic University

Boca Raton, Fla.

Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Empirical beam angle optimization for lung cancer intensity modulated radiation therapy
Other Title Info

Empirical beam angle optimization for lung cancer intensity modulated radiation therapy