Machined brass skin collimation with variable thickness for electron therapy

File
Publisher
Florida Atlantic University
Date Issued
2021
EDTF Date Created
2021
Description
Skin collimation in electron therapy ensures sharper penumbra and maximal protection to adjacent critical structures. It also provides a better clinical dose to the target and avoids recurrences at the periphery. The thickness of the electron skin collimation must be adequate for shielding purposes, not too thick to cause discomfort to the patient and be conformal to the skin. This study assessed the clinical potential of machined brass skin collimation with variable thickness. Brass transmission factors for 6, 9, and 12 MeV electron beams were measured and used to determine the skin collimation clinically acceptable thickness. Dosimetric performance of the variable thickness skin collimation was evaluated for 9 MeV electrons within a rectilinear water-equivalent phantom and a water-filled head phantom. Results showed the variable thickness skin collimation is dosimetrically equivalent to the uniform thickness collimation. Favorable dosimetric advantages for brass skin collimation for small electron fields were achieved.
Note

Includes bibliography.

Language
Type
Extent
75 p.
Subject (Topical)
Identifier
FA00013731
Rights

Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.

Additional Information
Includes bibliography.
Thesis (PMS)--Florida Atlantic University, 2021.
FAU Electronic Theses and Dissertations Collection
Date Backup
2021
Date Created Backup
2021
Date Text
2021
Date Created (EDTF)
2021
Date Issued (EDTF)
2021
Extension


FAU

IID
FA00013731
Organizations
Person Preferred Name

Gomez, Facenda Alianna

author

Graduate College
Physical Description

application/pdf
75 p.
Title Plain
Machined brass skin collimation with variable thickness for electron therapy
Use and Reproduction
Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

2021
2021
Florida Atlantic University

Boca Raton, Fla.

Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Machined brass skin collimation with variable thickness for electron therapy
Other Title Info

Machined brass skin collimation with variable thickness for electron therapy