Validity of Linear Position Transducers Versus the Optotrak Certus 3D Motion Capture System

File
Publisher
Florida Atlantic University
Date Issued
2016
EDTF Date Created
2016
Description
The purpose of this study was to investigate the validity of linear position
transducers (LPTs), The Open Barbell System (OBS) and Tendo Weightlifting Analyzer
System (TWAS), in comparison to criterion measure Optotrak Certus (OC3D). Further,
we aimed to compare LPTs against each other. Twenty-five resistance-trained males were
recruited, and reported to the laboratory for one day of data collection. Subjects
performed one-repetition maximum (1 RM) testing of the squat, then had a standardized
rest before completing one set to failure with 70% 1 RM. There was no significant
difference in average velocity (AV) between either LPT vs. OC3D. T-tests revealed
significant differences between LPTs and OC3D peak velocity (PV) (OBS: p=0.02080;
TWAS: p<0.01). A significant difference was detected between OBS and TWAS PV
(p<0.01). OBS and TWAS demonstrated concurrent validity compared to OC3D for AV
(OBS: p=0.2014; TWAS: p=0.5466). Neither LPT was a valid measure ofPV (OBS:
p=0.0208; TWAS: p<0.01).
Note

Includes bibliography.

Language
Type
Extent
66 p.
Identifier
FA00004711
Additional Information
Includes bibliography.
Thesis (M.S.)--Florida Atlantic University, 2016.
FAU Electronic Theses and Dissertations Collection
Date Backup
2016
Date Created Backup
2016
Date Text
2016
Date Created (EDTF)
2016
Date Issued (EDTF)
2016
Extension


FAU

IID
FA00004711
Organizations
Person Preferred Name

Goldsmith, Jacob A.

author

Graduate College
Physical Description

application/pdf
66 p.
Title Plain
Validity of Linear Position Transducers Versus the Optotrak Certus 3D Motion Capture System
Use and Reproduction
Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

2016
2016
Florida Atlantic University

Boca Raton, Fla.

Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Validity of Linear Position Transducers Versus the Optotrak Certus 3D Motion Capture System
Other Title Info