Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning

File
Publisher
Florida Atlantic University
Date Issued
2019
EDTF Date Created
2019
Description
The accuracy of proton dose computation in the treatment planning system relies on the conversion from the Hounsfield units (HU) of each voxel in the patient CT scan to the proton stopping power ratio (SPR). The aim of this study is to investigate the potential improvement in determining proton SPR using single energy computed tomography (SECT) to reduce the uncertainty in predicting the proton range in patients. Factors which may cause CT number variations in the calibration curve have been examined. The HU-SPR calibration curve was determined based on HU of human body tissues using the stoichiometric method. The uncertainties in SPR were divided into two major categories: The inherent uncertainty, and the CT number uncertainty. The root mean square errors of the inherent uncertainties were estimated 0.02%, 0.61% and 0.26% for lung tissues, soft tissues (excluding Thyroid), and bone tissues, respectively. The total uncertainties due to the inherent uncertainty and CT imaging errors were estimated 1.50%. The average calibration curve of two sized phantoms (head and body) were used in the treatment planning system to mitigate beam hardening effect through the attenuating media. A higher accuracy of the SPR prediction using the stoichiometric method is suggested through comparison with the predicted SPRs that derived from the direct calibration approach.
Note

Includes bibliography.

Language
Type
Extent
59 p.
Identifier
FA00013374
Rights

Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.

Additional Information
Includes bibliography.
Thesis (M.S.)--Florida Atlantic University, 2019.
FAU Electronic Theses and Dissertations Collection
Date Backup
2019
Date Created Backup
2019
Date Text
2019
Date Created (EDTF)
2019
Date Issued (EDTF)
2019
Extension


FAU

IID
FA00013374
Organizations
Person Preferred Name

Ghasemi Ghonchehnazi, Maryam

author

Graduate College
Physical Description

application/pdf
59 p.
Title Plain
Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning
Use and Reproduction
Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

2019
2019
Florida Atlantic University

Boca Raton, Fla.

Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning
Other Title Info

Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning