Sickle cell disease is an inherited blood cell disorder that affects about 100,000 people
in the US and results in high cost of medical care exceeding $1.1 billion annually. Sickle
cell patients suffer from unpredictable, painful vaso-occlusive crises. Portable, costeffective
approaches for diagnosis and monitoring sickle blood activities are important for
a better management of the disease and reducing the medical cost.
In this research, a mobile application controlled, impedance-based flow cytometer is
developed for the diagnosis of sickle cell disease. Calibration of the portable device is
performed using a component of known impedance value. The preliminary test results are
then compared to those obtained by a commercial benchtop impedance analyzer for further
validation. With the developed portable flow cytometer, experiments are performed on two
sickle cell samples and a healthy cell sample. The acquired results are subsequently
analyzed with MATLAB scripts to extract single-cell level impedance information as well as statistics of different cell conditions. Significant differences in cell impedance signals
are observed between sickle cells and normal cells, as well as between sickle cells under
hypoxia and normoxia conditions.
Note

Includes bibliography.

Language
Type
Extent
57 p.
Identifier
FA00013145
Additional Information
Includes bibliography.
Thesis (M.S.)--Florida Atlantic University, 2018.
FAU Electronic Theses and Dissertations Collection
Date Backup
2018
Date Created Backup
2018
Date Text
2018
Date Created (EDTF)
2018
Date Issued (EDTF)
2018
Extension


FAU

IID
FA00013145
Person Preferred Name

Dieujuste, Darryl

author

Graduate College
Physical Description

application/pdf
57 p.
Title Plain
Development of A Portable Impedance Based Flow Cytometer for Diagnosis of Sickle Cell Disease
Use and Reproduction
Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

2018
2018
Florida Atlantic University

Boca Raton, Fla.

Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Development of A Portable Impedance Based Flow Cytometer for Diagnosis of Sickle Cell Disease
Other Title Info

Development of A Portable Impedance Based Flow Cytometer for Diagnosis of Sickle Cell Disease