Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy

File
Publisher
Florida Atlantic University
Date Issued
2020
EDTF Date Created
2020
Description
Physical cones equipped on GammaKnife, Cyberknife, and C-arm linacs have been the standard practice in Stereotactic Ablative Radiotherapy (SART) for small intracranial lesions, such as treating trigeminal or glossopharyngeal neuralgia targets. The advancement of high-definition multi-leaf collimators (HDMLC), treatment planning systems, and small field dosimetry now allows for treatment without the need for an auxiliary mounted physical cone. This treatment type uses the “virtual cone”, a permanent high-definition MLC, arrangement to deliver “very small fields” with comparable spherical dose distributions to physical cones. The virtual cone therapy, on a Varian Edge™ linac using multiple non-coplanar arcs with static HDMLCs, is a comparable technique that can be used to treat small intracranial neuralgia or other small lesions.
In this investigation, two flattening filter free (FFF) photon beams, 6MV FFF and 10MV FFF, were tested for optimal delivery and safety conditions for treating intracranial lesions. The virtual cone method on a Varian Edge™ Linear accelerator using rapid arc stereotactic radiosurgery was used to treat cranial neuralgia for chronic pain for six patients. Absolute dose, relative dose measurements, and monitor units were the main characteristics that were examined to decide which energy was the best for treatment. Source-to-axis distances (SAD) of 100cm measurements were taken at depths of 10cm and 5cm, respectively.
Note

Includes bibliography.

Language
Type
Extent
106 p.
Identifier
FA00013630
Rights

Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.

Additional Information
Includes bibliography.
Thesis (M.S.)--Florida Atlantic University, 2020.
FAU Electronic Theses and Dissertations Collection
Date Backup
2020
Date Created Backup
2020
Date Text
2020
Date Created (EDTF)
2020
Date Issued (EDTF)
2020
Extension


FAU

IID
FA00013630
Organizations
Person Preferred Name

Stevens, Ryan

author

Graduate College
Physical Description

application/pdf
106 p.
Title Plain
Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy
Use and Reproduction
Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

2020
2020
Florida Atlantic University

Boca Raton, Fla.

Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy
Other Title Info

Improved Methodology of Static HDMLC Virtual Cone based Rapid Arcs for Stereotactic Ablative Radiotherapy