Laboratory experiments have been performed to characterize the effects of initial current density and selected variables (initial current density, temperature and surface treatment) upon the cathodic polarization behavior of API 2H Grade 42 steel in natural sea water. The procedure involved galvanic coupling of a cylindrical steel specimen to a larger diameter aluminum sacrificial anode ring through an external resistor, which offset the otherwise impractically small anode/cathode surface area ratio and permitted the desired initial current density to be realized. In the initial polarization stage the change in potential versus current density data with time was found to be linear with a slope equal to the product of the total circuit resistance and cathode surface area and with the vertical intercept corresponding to the anode open circuit potential. Lower temperature or increased flow resulted in reduced polarization and a relatively high current density, but data for experiments employing a particular resistance conformed to straight lines with the same slope R[ext] x A[c] (external resistance times cathode surface area). Some experiments exhibited concave behavior at longer test duration. An explanation for the linear interdependence of potential and current density and the following concave behavior is presented. The laboratory experiments were compared with offshore structure survey results. It is projected that the potential-current density behavior of galvanic cathodic protection (CP) systems of different geometries can be quantitatively interrelated through this slope parameter. Implications of the data are discussed within the context of cathodic protection design, rapid polarization and system performance for offshore structures.