Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy

File
Publisher
Florida Atlantic University
Date Issued
2020
EDTF Date Created
2020
Description
In this work, we have developed a robust daily quality assurance (QA) system for pencil-beam scanning (PBS) dosimetry. A novel phantom and multi-PTV PBS plan were used in conjunction with the Sun Nuclear Daily QA3 multichamber detector array to verify output, range, and spot position. The sensitivity to detect change in these parameters with our designed tests was determined empirically. Associated tolerance levels were established based on these sensitivities and guidelines published in recent American Association of Physics in Medicine (AAPM) task group reports. The output has remained within the 3% tolerance and the range was within ±1mm. Spot position has remained within ±2mm. This daily QA procedure is quick and efficient with the time required for setup and delivery at less than 10 minutes.
Note

Includes bibliography.

Language
Type
Extent
71 p.
Identifier
FA00013623
Rights

Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.

Additional Information
Includes bibliography.
Thesis (M.S.)--Florida Atlantic University, 2020.
FAU Electronic Theses and Dissertations Collection
Date Backup
2020
Date Created Backup
2020
Date Text
2020
Date Created (EDTF)
2020
Date Issued (EDTF)
2020
Extension


FAU

IID
FA00013623
Organizations
Person Preferred Name

Kassel, Maxwell

author

Graduate College
Physical Description

application/pdf
71 p.
Title Plain
Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy
Use and Reproduction
Copyright © is held by the author with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

2020
2020
Florida Atlantic University

Boca Raton, Fla.

Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy
Other Title Info

Development of an Innovative Daily QA System for Pencil-Beam Scanning Proton Therapy