Feasibility of using carbon fiber reinforced plastic tendons in prestressed concrete Double-Tee bridge system

File
Publisher
Florida Atlantic University
Date Issued
1996
Description
One of the major problems the construction industry faces today is corrosion of reinforcing and prestressing steel, which significantly affects the durability of concrete structures. Fiber reinforced plastics (FRPs) are highly regarded as prospective replacement for steel in prestressed concrete structures under corrosive environment. This investigation was conducted to establish the feasibility of using Carbon Fiber Composite (CFC) cables as reinforcing/prestressing elements in concrete bridge structures. Besides investigating durability of CFC cables and pretensioned concrete beams with CFC cables in adverse environments (alkali and seawater), flexure and shear tests were performed on single Double-Tee beams, together with service load behavior, fatigue strength and ultimate load capacity tests on a half scale model Double-Tee girder bridge system prestressed with CFC cables. Exposure to seawater and alkali environments has no adverse effect on the strength of the CFRP tendons as well as the pretensioned beams with CFRP. Based on the flexural strength tests on Double-Tee beams, the bond between CFRP tendons and concrete is satisfactory. The Double-Tee bridge system exhibited good fatigue resistance and adequate ductility under ultimate load conditions. The ultimate load capacity of the bridge is approximately three times the service load corresponding to two HS20-44 trucks and equals 2.4 times the first crack load. Finite element analyses were carried out to predict elastic deformations and collapse load of the Double-Tee bridge prestressed with CFC cables. Feasibility of using CFC cables in bridge structures is assessed based on the experimental and analytical parameters such as deflections, strains, crack distributions and crack widths.
Note

College of Engineering and Computer Science

Language
Type
Extent
286 p.
Identifier
9780591029307
ISBN
9780591029307
Additional Information
College of Engineering and Computer Science
FAU Electronic Theses and Dissertations Collection
Thesis (Ph.D.)--Florida Atlantic University, 1996.
Date Backup
1996
Date Text
1996
Date Issued (EDTF)
1996
Extension


FAU
FAU
admin_unit="FAU01", ingest_id="ing1508", creator="staff:fcllz", creation_date="2007-07-18 20:33:08", modified_by="super:SPATEL", modification_date="2011-01-06 13:08:42"

IID
FADT12465
Issuance
monographic
Person Preferred Name

Zhuang, Ming.
Graduate College
Physical Description

286 p.
application/pdf
Title Plain
Feasibility of using carbon fiber reinforced plastic tendons in prestressed concrete Double-Tee bridge system
Use and Reproduction
Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
http://rightsstatements.org/vocab/InC/1.0/
Origin Information

1996
monographic

Boca Raton, Fla.

Florida Atlantic University
Physical Location
Florida Atlantic University Libraries
Place

Boca Raton, Fla.
Sub Location
Digital Library
Title
Feasibility of using carbon fiber reinforced plastic tendons in prestressed concrete Double-Tee bridge system
Other Title Info

Feasibility of using carbon fiber reinforced plastic tendons in prestressed concrete Double-Tee bridge system